Frequently Asked Questions About Domestic Refrigerator Repair:
Compressor replaced 2 months ago now not cooling
We have a 10 year old Admiral fridge with freezer on top. The compressor was replaced 2 months ago and I set the temp control to the highest setting. Now there is no cold air either up or down in either compartment. Any ideas?
Hmm, 2 months ago, if there is no cold at all the tech likely left a pin hole leak at one of the solder
joints. You should be able to see where it is as the presence of oil will be at the specific place of the leak. Touch the bottom on each solder joint in turn. You should shut this unit down immediately as running it in this situation may damage the new compressor.
|